Component: Simulation External Input (Runtime Tools)

From Flowcode Help
Revision as of 16:25, 7 January 2022 by Wiki bot (talk | contribs)
Jump to navigationJump to search
Author Matrix TSL
Version 1.1
Category Runtime Tools


Simulation External Input component

A simulation only component designed to allow a single digital pin to be toggled at a set frequency. Allows things like switch presses or external square waves to be used with the simulation.

Component Pack

FREE

Detailed description

No detailed description exists yet for this component

Examples

No additional examples


Downloadable macro reference

Fc9-comp-macro.png Control_Pulse
Controls if the toggle input is enabled or disabled allowing you to stop and start the waveform. 
Fc9-u8-icon.png - BYTE State
0=Disabled, 1=Enabled 
Fc9-void-icon.png - VOID Return


Fc9-comp-macro.png Get_Pulse_Count
Reads the number of pulses remaining in the current run. The Pulse Count property needs to have an initial value > 0 to switch on the pulse counting mode. 
Fc9-u32-icon.png - ULONG Return


Fc9-comp-macro.png Set_Space
Overrides the component property setting allowing for a variable frequency input or adjustable Space timings. 
Fc9-u16-icon.png - UINT Delay
Delay between transitiions in milliseconds. 
Fc9-void-icon.png - VOID Return


Fc9-comp-macro.png Set_Pulse_Count
Overrides the number of pulses. The Pulse Count property needs to have an initial value > 0 to switch on the pulse counting mode. 
Fc9-u32-icon.png - ULONG PulseCount
Number of pulses to output 
Fc9-void-icon.png - VOID Return


Fc9-comp-macro.png Set_Frequency
Allows the frequency to be changed on the fly 
Fc9-f32-icon.png - FLOAT Frequency
 
Fc9-void-icon.png - VOID Return


Fc9-comp-macro.png Set_Mark
Overrides the component property setting allowing for a variable frequency input or adjustable Mark timings. 
Fc9-u16-icon.png - UINT Delay
Delay between transitiions in milliseconds. 
Fc9-void-icon.png - VOID Return



Property reference

Fc9-prop-icon.png Properties
Fc9-type-5-icon.png Pin
Pin to toggle - connected to the external waveform on the target hardware. 
Fc9-type-16-icon.png Startup Mode
Controls if the pulses start when the simulation is started or when the simulation Control_Pulse macro is called. 
Fc9-type-16-icon.png Mode
 
Fc9-type-15-icon.png Frequency (Hz)
Frequency to try and acheive. 
Fc9-type-21-icon.png Period Delay (ms)
Delay in milliseconds for a whole period of 0 and 1. 
Fc9-type-21-icon.png Mark Delay (ms)
Delay in milliseconds to wait to toggle the pin. Note that Windows can only acheive timings of 10ms or more. 
Fc9-type-21-icon.png Space Delay (ms)
 
Fc9-type-21-icon.png Pulse Count
Number of pulses to output. 0 = Run forever. > 0 = Output the selected number of pulses 
Fc9-conn-icon.png Connections
Fc9-conn-icon.png Simulations