Component: Temperature Infrared (Grove 101020062) (Environmental)

From Flowcode Help
Revision as of 13:10, 7 February 2023 by Wiki bot (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigationJump to search
Author Matrix TSL
Version 1.2
Category Environmental


Temperature Infrared (Grove 101020062) component

The Grove Infrared Temperature Sensor allows none contact measurement of temperatures ranging from -10 to 100 degrees C.

Component Source Code

Please click here to download the component source project: FC_Comp_Source_GroveIRTemp.fcfx

Please click here to view the component source code (Beta): FC_Comp_Source_GroveIRTemp.fcfx

Detailed description

No detailed description exists yet for this component

Examples

No additional examples







Macro reference

MeasureObjectTemp

Fc9-comp-macro.png MeasureObjectTemp
Measures the temperature of the targetted object 
Fc9-f32-icon.png - FLOAT Return


MeasureSurTemp

Fc9-comp-macro.png MeasureSurTemp
Measures the surrounding ambient temperature, 
Fc9-f32-icon.png - FLOAT Return


Property reference

Fc9-prop-icon.png Properties
Fc9-type-6-icon.png Ambient Pin (SUR)
Analogue input channel - which pin is the analogue input conected to? 
Fc9-type-6-icon.png Object Pin (OBJ)
Analogue input channel - which pin is the analogue input conected to? 
Fc9-conn-icon.png ADC Properties
Fc9-type-14-icon.png VRef voltage
Used by the GetVoltage or GetString component macros to take an ADC reading and convert it into a Voltage. +VRef voltage x 10mV Default 500 = 5.0V  
Fc9-type-16-icon.png VRef option
Defines what is used as the ADC maximum reference. ADC Range = GND to VRef Voltage. VDD - Defines the microcontrollers power supply pin as the max reference, VREF+ Pin - Dedicated pin on the microcontroller to allow for a variable reference voltage.  
Fc9-type-16-icon.png Conversion speed
Clock setting to select how fast the ADC peripheral will perform an ADC conversion. The FRC setting is based on a RC time base and so will vary with temperature and pressure. Other settings are generally based on divisions of the master clock.  
Fc9-type-14-icon.png Acquisition cycles
Number of micro seconds to wait for the ACD input to charge before starting the analogue sample. 
Fc9-conn-icon.png Advanced Settings
Fc9-type-15-icon.png Temperature Calibration
Ambient temperature calibration value 
Fc9-type-15-icon.png Temperature Range
Map of temperature-voltage according to sensor datasheet. 10 is the temperature step when sensor and object distance is 9CM. 
Fc9-type-15-icon.png Offset Voltage
Voltage of mid level voltage after 5-10 mins to bring the sensor to ambient. 
Fc9-type-21-icon.png Number of Samples
Number of samples to take to average out each reading. Default 10.