PicoScope component
A set of functions designed for interacting with a 2000 series Pico scope via simulation.
Component Source Code
Please click here to download the component source project: FC_Comp_Source_PS2000.fcsx
Please click here to view the component source code (Beta): FC_Comp_Source_PS2000.fcsx
Detailed description
No detailed description exists yet for this component
Examples
No additional examples
Macro reference
ps2000_close_unit
ps2000_close_unit | |
This function shuts down an oscilloscope. | |
- INT | Handle |
The handle of the scope device to be closed | |
- INT | Return |
ps2000_flash_led
ps2000_flash_led | |
This function flashes the LED on the front of the scope without blocking the calling thread. | |
- INT | handle |
handle of the scope device | |
- INT | Return |
ps2000_get_timebase
ps2000_get_times_and_values
ps2000_get_times_and_values | |
- INT | Handle |
- LONG | times |
- INT | buffer_a |
- INT | buffer_b |
- INT | buffer_c |
- INT | buffer_d |
- INT | overflow |
- INT | time_units |
- LONG | no_of_samples |
- LONG | Return |
ps2000_get_unit_info
ps2000_get_values
ps2000_open_unit
ps2000_open_unit | |
Returns a handle to the opened unit Returns 0 if no unit found Returns -1 if unit failed to open | |
- INT | Return |
ps2000_open_unit_async
ps2000_open_unit_async | |
This function opens a scope without blocking the calling thread. | |
- INT | Return |
ps2000_open_unit_progress
ps2000_open_unit_progress | |
This function checks on the progress of a request made to ps2000aOpenUnitAsync to open a scope. | |
- INT | handle |
- INT | Progress |
- INT | Return |
ps2000_ready
ps2000_ready | |
- INT | Handle |
- INT | Return |
ps2000_run_block
ps2000_run_block | |
This function starts collecting data in block mode. | |
- INT | handle |
- LONG | no_of_samples |
- INT | timebase |
- INT | oversample |
- LONG | time_indisposed_ms |
- INT | Return |
ps2000_set_channel
ps2000_set_sig_gen_built_in
ps2000_set_trigger
ps2000_set_trigger | |
- INT | handle |
- INT | source |
- INT | threshold |
- INT | direction |
- INT | delay |
- INT | auto_trigger_ms |
- INT | Return |
ps2000_stop
ps2000_stop | |
This function stops the scope device from sampling data. If this function is called before a trigger event occurs, the oscilloscope may not contain valid data. | |
- INT | Handle |
- INT | Return |
Property reference