Component: Humidity (EBM016) (EBM Modules): Difference between revisions
Appearance
No edit summary |
m Text replacement - "style="background-color:#EAE1EA;"" to "class="mtx-class-propfolder"" |
||
| (12 intermediate revisions by 2 users not shown) | |||
| Line 16: | Line 16: | ||
==Component Source Code== | ==Component Source Code== | ||
Please click here to download the component source project: [https://www.flowcode.co.uk/wiki/componentsource/FC_Comp_Source_EBM016v1.fcfx FC_Comp_Source_EBM016v1.fcfx] | |||
Please click here to view the component source code (Beta): [https://www.flowcode.co.uk/FlowchartView/?wfile=componentsource/FC_Comp_Source_EBM016v1.fcfx FC_Comp_Source_EBM016v1.fcfx] | Please click here to view the component source code (Beta): [https://www.flowcode.co.uk/FlowchartView/?wfile=componentsource/FC_Comp_Source_EBM016v1.fcfx FC_Comp_Source_EBM016v1.fcfx] | ||
==Detailed description== | ==Detailed description== | ||
| Line 40: | Line 48: | ||
==Examples== | ==Examples== | ||
| Line 63: | Line 77: | ||
{{Fcfile|EBM016 - Test Program.fcfx|EBM016 Example}} | {{Fcfile|EBM016 - Test Program.fcfx|EBM016 Example}} | ||
==Macro reference== | |||
{| class="wikitable | ===GetHumidityData=== | ||
{| class="mtx-class-macrotable wikitable" | |||
|- | |- | ||
| width="10%" align="center" | | width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | ||
| width="90%" | | width="90%" class="mtx-class-macrohead" | '''GetHumidityData''' | ||
|- | |- | ||
| colspan="2" | Returns the raw register pair value | | colspan="2" | Returns the raw register pair value | ||
| Line 143: | Line 103: | ||
{| class="wikitable | ===GetHumidityInt=== | ||
{| class="mtx-class-macrotable wikitable" | |||
|- | |- | ||
| width="10%" align="center" | | width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | ||
| width="90%" | | width="90%" class="mtx-class-macrohead" | '''GetHumidityInt''' | ||
|- | |- | ||
| colspan="2" | | | colspan="2" | returns the relative Humidity reading as an integer value | ||
|- | |- | ||
|- | |- | ||
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9- | | width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-s16-icon.png]] - INT | ||
| width="90%" style="border-top: 2px solid #000;" | ''Return'' | | width="90%" style="border-top: 2px solid #000;" | ''Return'' | ||
|} | |} | ||
===GetHumidityReal=== | |||
{| class="mtx-class-macrotable wikitable" | |||
== | |||
{| class="wikitable | |||
|- | |- | ||
| width="10%" align="center" | | width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | ||
| width="90%" | | width="90%" class="mtx-class-macrohead" | '''GetHumidityReal''' | ||
|- | |- | ||
| colspan="2" | returns the Humidity reading as a float value | |||
| colspan="2" | | |||
|- | |- | ||
|- | |- | ||
| Line 219: | Line 131: | ||
{| class="wikitable | ===GetTemperatureData=== | ||
{| class="mtx-class-macrotable wikitable" | |||
|- | |- | ||
| width="10%" align="center" | | width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | ||
| width="90%" | | width="90%" class="mtx-class-macrohead" | '''GetTemperatureData''' | ||
|- | |- | ||
| colspan="2" | Returns the raw register pair value | | colspan="2" | Returns the raw register pair value | ||
| Line 232: | Line 145: | ||
{| class="wikitable | ===GetTemperatureInt=== | ||
{| class="mtx-class-macrotable wikitable" | |||
|- | |- | ||
| width="10%" align="center" | | width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | ||
| width="90%" | | width="90%" class="mtx-class-macrohead" | '''GetTemperatureInt''' | ||
|- | |- | ||
| colspan="2" | Return temperature reading as an integer value in degrees C | | colspan="2" | Return temperature reading as an integer value in degrees C | ||
| Line 245: | Line 159: | ||
{| class="wikitable | ===GetTemperatureReal=== | ||
{| class="mtx-class-macrotable wikitable" | |||
|- | |- | ||
| width="10%" align="center" | | width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | ||
| width="90%" | | width="90%" class="mtx-class-macrohead" | '''GetTemperatureReal''' | ||
|- | |- | ||
| colspan="2" | | | colspan="2" | Return temperature reading as a float value in degrees C | ||
|- | |- | ||
|- | |- | ||
| Line 271: | Line 173: | ||
===Initialise=== | |||
{| class="mtx-class-macrotable wikitable" | |||
| | |||
|- | |- | ||
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | |||
| width="10%" align="center" | | width="90%" class="mtx-class-macrohead" | '''Initialise''' | ||
| width="90%" | |||
|- | |- | ||
| colspan="2" | Initialises the component ready for I2C communications | | colspan="2" | Initialises the component ready for I2C communications | ||
| Line 295: | Line 185: | ||
| width="90%" style="border-top: 2px solid #000;" | ''Return'' | | width="90%" style="border-top: 2px solid #000;" | ''Return'' | ||
|} | |} | ||
==Property reference== | ==Property reference== | ||
{| class="wikitable | {| class="mtx-class-macrotable wikitable" | ||
|- | |- | ||
| width="10%" align="center" | | width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-prop-icon.png]] | ||
| width="90%" | | width="90%" class="mtx-class-macrohead" | '''Properties''' | ||
|- | |- | ||
|- | |- | ||
| Line 337: | Line 225: | ||
| colspan="2" | On older microcontroller devices there is a potential for the I2C hardware channel to lock up if there is not a 10ms delay between an I2C stop event and the next I2C start event. Most modern microcontrollers will not have a problem so this property can be disabled to speed up the I2C communications. | | colspan="2" | On older microcontroller devices there is a potential for the I2C hardware channel to lock up if there is not a 10ms delay between an I2C stop event and the next I2C start event. Most modern microcontrollers will not have a problem so this property can be disabled to speed up the I2C communications. | ||
|- | |- | ||
| width="10%" align="center" | | width="10%" align="center" class="mtx-class-propfolder" | [[File:Fc9-conn-icon.png]] | ||
| width="90%" | | width="90%" class="mtx-class-propfolder" | Simulation | ||
|- | |- | ||
|- | |- | ||
Latest revision as of 14:36, 13 July 2026
| Author | Matrix TSL |
| Version | 2.0 |
| Category | EBM Modules |
Humidity component
Humidity and temperature sensor using an SHT21 IC connected via I2C - as used by the Matrix e-block module EBM016. On screen GUI allows temperature and humidity values to be simulated, and will show all I2C communication in a console window.
Component Source Code
Please click here to download the component source project: FC_Comp_Source_EBM016v1.fcfx
Please click here to view the component source code (Beta): FC_Comp_Source_EBM016v1.fcfx
Detailed description
No detailed description exists yet for this component
Examples
This example reads the temperature and humidity levels from the sensor and displays the readings on the LCD.
Macro reference
GetHumidityData
| GetHumidityData | |
| Returns the raw register pair value | |
| Return | |
GetHumidityInt
| GetHumidityInt | |
| returns the relative Humidity reading as an integer value | |
| Return | |
GetHumidityReal
| GetHumidityReal | |
| returns the Humidity reading as a float value | |
| Return | |
GetTemperatureData
| GetTemperatureData | |
| Returns the raw register pair value | |
| Return | |
GetTemperatureInt
| GetTemperatureInt | |
| Return temperature reading as an integer value in degrees C | |
| Return | |
GetTemperatureReal
| GetTemperatureReal | |
| Return temperature reading as a float value in degrees C | |
| Return | |
Initialise
| Initialise | |
| Initialises the component ready for I2C communications | |
| Return | |