Difference between revisions of "Component: Modbus Slave (SCADA) (Comms: System)"
From Flowcode Help
Jump to navigationJump to search| (2 intermediate revisions by the same user not shown) | |||
| Line 17: | Line 17: | ||
==Component Source Code== | ==Component Source Code== | ||
| − | Please click here to download the component source project: [https://www.flowcode.co.uk/wiki/componentsource/ | + | Please click here to download the component source project: [https://www.flowcode.co.uk/wiki/componentsource/FC_Comp_Source_Modbus_Slave_SCADA.fcsx FC_Comp_Source_Modbus_Slave_SCADA.fcsx] |
| − | Please click here to view the component source code (Beta): [https://www.flowcode.co.uk/FlowchartView/?wfile=componentsource/ | + | Please click here to view the component source code (Beta): [https://www.flowcode.co.uk/FlowchartView/?wfile=componentsource/FC_Comp_Source_Modbus_Slave_SCADA.fcsx FC_Comp_Source_Modbus_Slave_SCADA.fcsx] |
==Detailed description== | ==Detailed description== | ||
| Line 73: | Line 73: | ||
''<span style="color:red;">No additional examples</span>'' | ''<span style="color:red;">No additional examples</span>'' | ||
| + | |||
| + | |||
| + | |||
| + | |||
| + | |||
| + | |||
| Line 124: | Line 130: | ||
| colspan="2" | Gets a value from the last incoming command. Index 0 = 0 Read / 1 Write Index 1 = 0 Coils / 1 DigInput / 2 AnInput / 3 Register Index 2 = Address Index 3 = Number | | colspan="2" | Gets a value from the last incoming command. Index 0 = 0 Read / 1 Write Index 1 = 0 Coils / 1 DigInput / 2 AnInput / 3 Register Index 2 = Address Index 3 = Number | ||
|- | |- | ||
| + | |- | ||
| + | | width="10%" align="center" | [[File:Fc9-u8-icon.png]] - BYTE | ||
| + | | width="90%" | Index | ||
| + | |- | ||
| + | | colspan="2" | Range: 0-3 | ||
|- | |- | ||
| width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-u16-icon.png]] - UINT | | width="10%" align="center" style="border-top: 2px solid #000;" | [[File:Fc9-u16-icon.png]] - UINT | ||
| Line 343: | Line 354: | ||
| width="90%" style="border-top: 2px solid #000;" | ''Return'' | | width="90%" style="border-top: 2px solid #000;" | ''Return'' | ||
|} | |} | ||
| − | |||
| − | |||
Latest revision as of 10:26, 20 October 2023
| Author | Matrix TSL |
| Version | 1.0 |
| Category | Comms: System |
Contents
Modbus Slave (SCADA) component
Modbus component for creating Modbus compatible slave hardware via RS232 or RS485.
Component Source Code
Please click here to download the component source project: FC_Comp_Source_Modbus_Slave_SCADA.fcsx
Please click here to view the component source code (Beta): FC_Comp_Source_Modbus_Slave_SCADA.fcsx
Detailed description
No detailed description exists yet for this component
Examples
No additional examples
Macro reference
ChangeFrameType
| ChangeFrameType | |
| Default frame type is the type set in the component properties. | |
| Type | |
| 0 = Modbus RTU / 1 = Modbus ASCII | |
| Return | |
CheckForIncoming
GetLastIncoming
Initialise
| Initialise | |
| Starts up the UART to allow communications and initialises the states of the various Modbus Coils, Inputs and Registers to 0. | |
| Return | |
ReadAnalogInput
| ReadAnalogInput | |
| Reads the value of a single analogue input. | |
| Address | |
| Coil Address | |
| Return | |
ReadCoils
ReadDigitalInputs
ReadHoldingRegister
| ReadHoldingRegister | |
| Reads the value of a single holding register. | |
| Address | |
| Coil Address | |
| Return | |
SetAnalogInput
| SetAnalogInput | |
| Sets the state of a single analogue input. | |
| Address | |
| Coil Address | |
| Value | |
| Analogue Value range 0 - 65535 | |
| Return | |
SetCoil
| SetCoil | |
| Sets the state of a single digital coil. | |
| Address | |
| Coil Address | |
| State | |
| 0=off, 1=on | |
| Return | |
SetDigitalInput
| SetDigitalInput | |
| Sets the state of a single digital input. | |
| Address | |
| Coil Address | |
| State | |
| 0=off, 1=on | |
| Return | |
SetHoldingRegister
| SetHoldingRegister | |
| Sets the state of a single holding register. | |
| Address | |
| Coil Address | |
| Value | |
| Analogue Value range 0 - 65535 | |
| Return | |
SetSlaveAddress