Jump to content

Component: Temp / Humidity (DHT11) (Environmental): Difference between revisions

From Flowcode Help
No edit summary
m Text replacement - "style="background-color:#EAE1EA;"" to "class="mtx-class-propfolder""
 
(6 intermediate revisions by 2 users not shown)
Line 17: Line 17:
==Component Source Code==
==Component Source Code==


Please click here to download the component source project: [https://www.flowcode.co.uk/wiki/componentsource/FC_Comp_Source_temp/DHT11.fcfx FC_Comp_Source_temp/DHT11.fcfx]
Please click here to download the component source project: [https://www.flowcode.co.uk/wiki/componentsource/FC_Comp_Source_DHT11.fcfx FC_Comp_Source_DHT11.fcfx]


Please click here to view the component source code (Beta): [https://www.flowcode.co.uk/FlowchartView/?wfile=componentsource/FC_Comp_Source_temp/DHT11.fcfx FC_Comp_Source_temp/DHT11.fcfx]
Please click here to view the component source code (Beta): [https://www.flowcode.co.uk/FlowchartView/?wfile=componentsource/FC_Comp_Source_DHT11.fcfx FC_Comp_Source_DHT11.fcfx]


==Detailed description==
==Detailed description==
Line 74: Line 74:
Example Program showing how to sample the DHT11 sensor and show the temperature and humidity on an LCD.
Example Program showing how to sample the DHT11 sensor and show the temperature and humidity on an LCD.
{{Fcfile|DHT11_Example.fcfx|DHT11 Example}}
{{Fcfile|DHT11_Example.fcfx|DHT11 Example}}




Line 86: Line 88:


===GetHumidityFloat===
===GetHumidityFloat===
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
{| class="mtx-class-macrotable wikitable"
|-
|-
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]]
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''GetHumidityFloat'''
| width="90%" class="mtx-class-macrohead" | '''GetHumidityFloat'''
|-
|-
| colspan="2" | Gets the humidity returned by calling SampleSensor as a floating point number.  
| colspan="2" | Gets the humidity returned by calling SampleSensor as a floating point number.  
Line 100: Line 102:


===GetHumidityReal===
===GetHumidityReal===
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
{| class="mtx-class-macrotable wikitable"
|-
|-
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]]
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''GetHumidityReal'''
| width="90%" class="mtx-class-macrohead" | '''GetHumidityReal'''
|-
|-
| colspan="2" | Gets the real number portion of the humidity returned by calling SampleSensor. If humidity is 15.8 % then this function would return 8. 
| colspan="2" | Gets the real number portion of the humidity returned by calling SampleSensor. If humidity is 15.8 % then this function would return 8. 
Line 114: Line 116:


===GetHumidityString===
===GetHumidityString===
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
{| class="mtx-class-macrotable wikitable"
|-
|-
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]]
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''GetHumidityString'''
| width="90%" class="mtx-class-macrohead" | '''GetHumidityString'''
|-
|-
| colspan="2" | Gets the humidity returned by calling SampleSensor as a string.  
| colspan="2" | Gets the humidity returned by calling SampleSensor as a string.  
Line 128: Line 130:


===GetHumidityWhole===
===GetHumidityWhole===
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
{| class="mtx-class-macrotable wikitable"
|-
|-
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]]
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''GetHumidityWhole'''
| width="90%" class="mtx-class-macrohead" | '''GetHumidityWhole'''
|-
|-
| colspan="2" | Gets the whole number portion of the humidity returned by calling SampleSensor. If humidity is 15.8 % then this function would return 15. 
| colspan="2" | Gets the whole number portion of the humidity returned by calling SampleSensor. If humidity is 15.8 % then this function would return 15. 
Line 142: Line 144:


===GetTempFloat===
===GetTempFloat===
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
{| class="mtx-class-macrotable wikitable"
|-
|-
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]]
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''GetTempFloat'''
| width="90%" class="mtx-class-macrohead" | '''GetTempFloat'''
|-
|-
| colspan="2" | Gets the temperature returned by calling SampleSensor as a floating point number.  
| colspan="2" | Gets the temperature returned by calling SampleSensor as a floating point number.  
Line 156: Line 158:


===GetTempReal===
===GetTempReal===
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
{| class="mtx-class-macrotable wikitable"
|-
|-
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]]
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''GetTempReal'''
| width="90%" class="mtx-class-macrohead" | '''GetTempReal'''
|-
|-
| colspan="2" | Gets the real number portion of the temperature returned by calling SampleSensor. If temperature is 15.8 degrees C then this function would return 8. 
| colspan="2" | Gets the real number portion of the temperature returned by calling SampleSensor. If temperature is 15.8 degrees C then this function would return 8. 
Line 170: Line 172:


===GetTempString===
===GetTempString===
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
{| class="mtx-class-macrotable wikitable"
|-
|-
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]]
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''GetTempString'''
| width="90%" class="mtx-class-macrohead" | '''GetTempString'''
|-
|-
| colspan="2" | Gets the temperature returned by calling SampleSensor as a string.  
| colspan="2" | Gets the temperature returned by calling SampleSensor as a string.  
Line 184: Line 186:


===GetTempWhole===
===GetTempWhole===
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
{| class="mtx-class-macrotable wikitable"
|-
|-
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]]
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''GetTempWhole'''
| width="90%" class="mtx-class-macrohead" | '''GetTempWhole'''
|-
|-
| colspan="2" | Gets the whole number portion of the temperature returned by calling SampleSensor. If temperature is 15.8 degrees C then this function would return 15. 
| colspan="2" | Gets the whole number portion of the temperature returned by calling SampleSensor. If temperature is 15.8 degrees C then this function would return 15. 
Line 198: Line 200:


===SampleSensor===
===SampleSensor===
{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
{| class="mtx-class-macrotable wikitable"
|-
|-
| width="10%" align="center" style="background-color:#D8C9D8;" align="center" | [[File:Fc9-comp-macro.png]]
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]]
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''SampleSensor'''
| width="90%" class="mtx-class-macrohead" | '''SampleSensor'''
|-
|-
| colspan="2" | Communicates with the DHT11 sensor and receives the temperature and humidity readings. Returns 0 for success, 1 for no communication detected and 2 for checksum error. 
| colspan="2" | Communicates with the DHT11 sensor and receives the temperature and humidity readings. Returns 0 for success, 1 for no communication detected and 2 for checksum error. 
Line 213: Line 215:
==Property reference==
==Property reference==


{| class="wikitable" style="width:60%; background-color:#FFFFFF;"
{| class="mtx-class-macrotable wikitable"
|-
|-
| width="10%" align="center" style="background-color:#D8C9D8;" | [[File:Fc9-prop-icon.png]]
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-prop-icon.png]]
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''Properties'''  
| width="90%" class="mtx-class-macrohead" | '''Properties'''  
|-
|-
|-
|-
Line 229: Line 231:
| colspan="2" | The checksum value is used to ensure the data being received is correct. Yes = Only receive data if checksum is correct No = Ignore checksum 
| colspan="2" | The checksum value is used to ensure the data being received is correct. Yes = Only receive data if checksum is correct No = Ignore checksum 
|-
|-
| width="10%" align="center" style="background-color:#EAE1EA;" | [[File:Fc9-conn-icon.png]]
| width="10%" align="center" class="mtx-class-propfolder" | [[File:Fc9-conn-icon.png]]
| width="90%" style="background-color:#EAE1EA; color:#4B008D;" | Advanced Settings
| width="90%" class="mtx-class-propfolder" | Advanced Settings
|-
|-
|-
|-

Latest revision as of 14:37, 13 July 2026

Author Matrix TSL
Version 1.1
Category Environmental


Temp / Humidity (DHT11) component

The DHT11 temperature and humidity sensor is a popular sensor allowing the ambient temperature and relative humidity to be monitored digitally. Humidity Range = 20% - 90% +/- 5% Temperature Range = 0 - 50 Degrees C +/- 2 Degrees C

Component Source Code

Please click here to download the component source project: FC_Comp_Source_DHT11.fcfx

Please click here to view the component source code (Beta): FC_Comp_Source_DHT11.fcfx

Detailed description

No detailed description exists yet for this component

Examples

Example Program showing how to sample the DHT11 sensor and show the temperature and humidity on an LCD. DHT11 Example






Macro reference

GetHumidityFloat

GetHumidityFloat
Gets the humidity returned by calling SampleSensor as a floating point number.  
- FLOAT Return


GetHumidityReal

GetHumidityReal
Gets the real number portion of the humidity returned by calling SampleSensor. If humidity is 15.8 % then this function would return 8. 
- INT Return


GetHumidityString

GetHumidityString
Gets the humidity returned by calling SampleSensor as a string.  
- STRING Return


GetHumidityWhole

GetHumidityWhole
Gets the whole number portion of the humidity returned by calling SampleSensor. If humidity is 15.8 % then this function would return 15. 
- INT Return


GetTempFloat

GetTempFloat
Gets the temperature returned by calling SampleSensor as a floating point number.  
- FLOAT Return


GetTempReal

GetTempReal
Gets the real number portion of the temperature returned by calling SampleSensor. If temperature is 15.8 degrees C then this function would return 8. 
- INT Return


GetTempString

GetTempString
Gets the temperature returned by calling SampleSensor as a string.  
- STRING Return


GetTempWhole

GetTempWhole
Gets the whole number portion of the temperature returned by calling SampleSensor. If temperature is 15.8 degrees C then this function would return 15. 
- INT Return


SampleSensor

SampleSensor
Communicates with the DHT11 sensor and receives the temperature and humidity readings. Returns 0 for success, 1 for no communication detected and 2 for checksum error. 
- BYTE Return


Property reference

Properties
Data Pin
Microcontroller I/O Pin connected to the DHT11 sensor data pin. 
Use Checksum
The checksum value is used to ensure the data being received is correct. Yes = Only receive data if checksum is correct No = Ignore checksum 
Advanced Settings
Clock Adjustment
On 8-bit PIC devices the timings can be a little tight as slower clock speeds and so we implement an adjustment factor to allow the sensor to function. Auto mode will attempt to automatically calculate a correct adjustment factor. Manual mode will allow you to set your own adjustment factor.