Component: Modbus TCP Master (Comms: System): Difference between revisions
m Text replacement - "width="10%" align="center" style="background-color:#D8C9D8;"" to "width="10%" align="center" class="mtx-class-macrohead"" |
m Text replacement - "width="90%" style="background-color:#D8C9D8; color:#4B008D;"" to "width="90%" class="mtx-class-macrohead"" |
||
| Line 109: | Line 109: | ||
|- | |- | ||
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | | width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | ||
| width="90%" | | width="90%" class="mtx-class-macrohead" | '''GetResponseByte''' | ||
|- | |- | ||
| colspan="2" | Reads a byte from the last received response. The Index parametes specifies which byte to read back. | | colspan="2" | Reads a byte from the last received response. The Index parametes specifies which byte to read back. | ||
| Line 128: | Line 128: | ||
|- | |- | ||
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | | width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | ||
| width="90%" | | width="90%" class="mtx-class-macrohead" | '''GetResponseInt''' | ||
|- | |- | ||
| colspan="2" | Reads a 16-bit value from the last received response. The Index parametes specifies the byte index of the value to read back. | | colspan="2" | Reads a 16-bit value from the last received response. The Index parametes specifies the byte index of the value to read back. | ||
| Line 147: | Line 147: | ||
|- | |- | ||
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | | width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | ||
| width="90%" | | width="90%" class="mtx-class-macrohead" | '''ReadAnalogInput''' | ||
|- | |- | ||
| colspan="2" | This command requests the analogue input register values starting from the start RegAddress and going through to RegAddress plus RegCount. Returns 0 for success, 1 for CRC fail and 255 for no reply. | | colspan="2" | This command requests the analogue input register values starting from the start RegAddress and going through to RegAddress plus RegCount. Returns 0 for success, 1 for CRC fail and 255 for no reply. | ||
| Line 176: | Line 176: | ||
|- | |- | ||
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | | width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | ||
| width="90%" | | width="90%" class="mtx-class-macrohead" | '''ReadCoils''' | ||
|- | |- | ||
| colspan="2" | This command requests the ON/OFF status of discrete coils starting from the start CoilAddress and going through to CoilAddress plus CoilCount. Returns 0 for success, 1 for CRC fail and 255 for no reply. | | colspan="2" | This command requests the ON/OFF status of discrete coils starting from the start CoilAddress and going through to CoilAddress plus CoilCount. Returns 0 for success, 1 for CRC fail and 255 for no reply. | ||
| Line 205: | Line 205: | ||
|- | |- | ||
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | | width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | ||
| width="90%" | | width="90%" class="mtx-class-macrohead" | '''ReadDigitalInputs''' | ||
|- | |- | ||
| colspan="2" | This command requests the ON/OFF status of discrete inputs starting from the start DataAddress and going through to DataAddress plus DataCount. Returns 0 for success, 1 for CRC fail and 255 for no reply. | | colspan="2" | This command requests the ON/OFF status of discrete inputs starting from the start DataAddress and going through to DataAddress plus DataCount. Returns 0 for success, 1 for CRC fail and 255 for no reply. | ||
| Line 234: | Line 234: | ||
|- | |- | ||
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | | width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | ||
| width="90%" | | width="90%" class="mtx-class-macrohead" | '''ReadHoldingRegister''' | ||
|- | |- | ||
| colspan="2" | This command requests the analogue holding register values starting from the start RegAddress and going through to RegAddress plus RegCount. Returns 0 for success, 1 for CRC fail and 255 for no reply. | | colspan="2" | This command requests the analogue holding register values starting from the start RegAddress and going through to RegAddress plus RegCount. Returns 0 for success, 1 for CRC fail and 255 for no reply. | ||
| Line 263: | Line 263: | ||
|- | |- | ||
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | | width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | ||
| width="90%" | | width="90%" class="mtx-class-macrohead" | '''SetCoil''' | ||
|- | |- | ||
| colspan="2" | This command writes the contents of a discrete coil at the location CoilAddress. Returns 0 for success, 1 for CRC fail and 255 for no reply. | | colspan="2" | This command writes the contents of a discrete coil at the location CoilAddress. Returns 0 for success, 1 for CRC fail and 255 for no reply. | ||
| Line 292: | Line 292: | ||
|- | |- | ||
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | | width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | ||
| width="90%" | | width="90%" class="mtx-class-macrohead" | '''SetCoils''' | ||
|- | |- | ||
| colspan="2" | This command writes the contents of a series of discrete coils at the location starting at CoilAddress through to CoilAddress + CoilCount. Returns 0 for success, 1 for CRC fail and 255 for no reply. | | colspan="2" | This command writes the contents of a series of discrete coils at the location starting at CoilAddress through to CoilAddress + CoilCount. Returns 0 for success, 1 for CRC fail and 255 for no reply. | ||
| Line 326: | Line 326: | ||
|- | |- | ||
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | | width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | ||
| width="90%" | | width="90%" class="mtx-class-macrohead" | '''SetHoldingRegister''' | ||
|- | |- | ||
| colspan="2" | This command writes the contents of a analogue output holding register at the location RegAddress. Returns 0 for success, 1 for CRC fail and 255 for no reply. | | colspan="2" | This command writes the contents of a analogue output holding register at the location RegAddress. Returns 0 for success, 1 for CRC fail and 255 for no reply. | ||
| Line 355: | Line 355: | ||
|- | |- | ||
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | | width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | ||
| width="90%" | | width="90%" class="mtx-class-macrohead" | '''SetHoldingRegisters''' | ||
|- | |- | ||
| colspan="2" | This command writes the contents of several analogue output holding registers starting at the location RegAddress through to location RegAddress + RegCount . Returns 0 for success, 1 for CRC fail and 255 for no reply. | | colspan="2" | This command writes the contents of several analogue output holding registers starting at the location RegAddress through to location RegAddress + RegCount . Returns 0 for success, 1 for CRC fail and 255 for no reply. | ||
| Line 389: | Line 389: | ||
|- | |- | ||
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | | width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | ||
| width="90%" | | width="90%" class="mtx-class-macrohead" | '''SetTCPAddress''' | ||
|- | |- | ||
| colspan="2" | Sets the address of the remote TCP Slave that we wish to control. | | colspan="2" | Sets the address of the remote TCP Slave that we wish to control. | ||
| Line 409: | Line 409: | ||
|- | |- | ||
| width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-prop-icon.png]] | | width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-prop-icon.png]] | ||
| width="90%" | | width="90%" class="mtx-class-macrohead" | '''Properties''' | ||
|- | |- | ||
|- | |- | ||
Revision as of 14:23, 13 July 2026
| Author | Matrix Ltd. |
| Version | 2.1 |
| Category | Comms: System |
Modbus TCP Master component
Modbus component for talking to Modbus compatible hardware via Ethernet or WIFI. Ensure TCP/IP or WIFI component is initialised and connected to a network before calling the ModbusMasterTCP component macros.
Component Source Code
Please click here to download the component source project: FC_Comp_Source_ModbusTCP.fcfx
Please click here to view the component source code (Beta): FC_Comp_Source_ModbusTCP.fcfx
Detailed description
No detailed description exists yet for this component
Examples
Example master program to control the slave. The example sets coil address 0, clears coil address 0, reads an input register and outputs to the LCD. Be sure to set the IP address of the slave device at the top of the program. If you are simulating then use the IP address of the PC running the Slave simulation. Both programs can be simulated on the same PC using two instances of Flowcode.
Example slave program to react to the signals from the master. The example listens for Modbus commands from the master and outputs the current coils 0 state to an LED connected to PortA. The input register is loaded with a value which is incremented on each Modbus transaction.
Addressing
In Modbus the addressing protocol looks like this.
| Data Type | Common name | Starting address | Ending Address | Flowcode Start Address | Flowcode End Address |
| Modbus Coils | Bits, binary values, flags | 00001 | 10000 | 0 | 9999 |
| Digital Inputs | Binary inputs | 10001 | 30000 | 0 | 19999 |
| Analog Inputs | Binary inputs | 30001 | 40000 | 0 | 9999 |
| Modbus Registers | Analog values, variables | 40001 | 60000 | 0 | 19999 |
In Flowcode each section starts from 0 so the address range is as shown.
Macro reference
GetResponseByte
GetResponseInt
| GetResponseInt | |
| Reads a 16-bit value from the last received response. The Index parametes specifies the byte index of the value to read back. | |
| Index | |
| 3=data0, 5=data1, 7=data2, .. | |
| Return | |
ReadAnalogInput
ReadCoils
ReadDigitalInputs
ReadHoldingRegister
SetCoil
SetCoils
SetHoldingRegister
SetHoldingRegisters
SetTCPAddress
| SetTCPAddress | |
| Sets the address of the remote TCP Slave that we wish to control. | |
| Address | |
| e.g. "192.168.1.1" | |
| Return | |