Component: Pulse Oximeter (Max30100) (Environmental): Difference between revisions
Appearance
m Text replacement - "class="wikitable" style="width:60%; background-color:#FFFFFF;"" to "class="mtx-class-macrotable wikitable"" |
m Text replacement - "width="10%" align="center" style="background-color:#D8C9D8;" align="center"" to "width="10%" align="center" class="mtx-class-macrohead"" |
||
| Line 82: | Line 82: | ||
{| class="mtx-class-macrotable wikitable" | {| class="mtx-class-macrotable wikitable" | ||
|- | |- | ||
| width="10%" align="center" | | width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | ||
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''Initialise''' | | width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''Initialise''' | ||
|- | |- | ||
| Line 96: | Line 96: | ||
{| class="mtx-class-macrotable wikitable" | {| class="mtx-class-macrotable wikitable" | ||
|- | |- | ||
| width="10%" align="center" | | width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | ||
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''ReadIR''' | | width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''ReadIR''' | ||
|- | |- | ||
| Line 110: | Line 110: | ||
{| class="mtx-class-macrotable wikitable" | {| class="mtx-class-macrotable wikitable" | ||
|- | |- | ||
| width="10%" align="center" | | width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | ||
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''ReadRed''' | | width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''ReadRed''' | ||
|- | |- | ||
| Line 124: | Line 124: | ||
{| class="mtx-class-macrotable wikitable" | {| class="mtx-class-macrotable wikitable" | ||
|- | |- | ||
| width="10%" align="center" | | width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | ||
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''SetHighResModeEnabled''' | | width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''SetHighResModeEnabled''' | ||
|- | |- | ||
| Line 143: | Line 143: | ||
{| class="mtx-class-macrotable wikitable" | {| class="mtx-class-macrotable wikitable" | ||
|- | |- | ||
| width="10%" align="center" | | width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | ||
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''SetLEDsCurrent''' | | width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''SetLEDsCurrent''' | ||
|- | |- | ||
| Line 167: | Line 167: | ||
{| class="mtx-class-macrotable wikitable" | {| class="mtx-class-macrotable wikitable" | ||
|- | |- | ||
| width="10%" align="center" | | width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | ||
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''SetLEDsPulseWidth''' | | width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''SetLEDsPulseWidth''' | ||
|- | |- | ||
| Line 186: | Line 186: | ||
{| class="mtx-class-macrotable wikitable" | {| class="mtx-class-macrotable wikitable" | ||
|- | |- | ||
| width="10%" align="center" | | width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | ||
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''SetSamplingRate''' | | width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''SetSamplingRate''' | ||
|- | |- | ||
| Line 205: | Line 205: | ||
{| class="mtx-class-macrotable wikitable" | {| class="mtx-class-macrotable wikitable" | ||
|- | |- | ||
| width="10%" align="center" | | width="10%" align="center" class="mtx-class-macrohead" | [[File:Fc9-comp-macro.png]] | ||
| width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''Update''' | | width="90%" style="background-color:#D8C9D8; color:#4B008D;" | '''Update''' | ||
|- | |- | ||
Revision as of 14:17, 13 July 2026
| Author | Matrix TSL |
| Version | 1.0 |
| Category | Environmental |
Pulse Oximeter (Max30100) component
Sensor designed to monitor heart rate and pulse omimetry. Connected using an I2C bus.
Component Source Code
Please click here to download the component source project: FC_Comp_Source_Max30100_Pulse_Oximeter.fcfx
Please click here to view the component source code (Beta): FC_Comp_Source_Max30100_Pulse_Oximeter.fcfx
Detailed description
No detailed description exists yet for this component
Examples
No additional examples
Macro reference
Initialise
ReadIR
| ReadIR | |
| Returns one of the FIFO IR readings from the last update | |
| Return | |
ReadRed
| ReadRed | |
| Returns one of the FIFO Red readings from the last update | |
| Return | |
SetHighResModeEnabled
| SetHighResModeEnabled | |
| Enabled | |
| Return | |
SetLEDsCurrent
| SetLEDsCurrent | |
| IR | |
| Range: 0-15 / 0=0mA, 1=4mA, .., 14=46mA, 15=50mA | |
| Red | |
| Range: 0-15 / 0=0mA, 1=4mA, .., 14=46mA, 15=50mA | |
| Return | |
SetLEDsPulseWidth
| SetLEDsPulseWidth | |
| PulseWidth | |
| Return | |
SetSamplingRate
| SetSamplingRate | |
| SampleRate | |
| Range: 0-7 / 0=50Hz, 1=100Hz, .., 6=800Hz, 7=1000Hz | |
| Return | |
Update
| Update | |
| Reads the sensor FIFO buffer and stores the readings into local RAM. Returns the number of samples read. | |
| Return | |